  • 标题:Assessment of indoor air quality related to potential vapor intrusion: Issues for former manufactured gas plants
  • 本地全文:下载
  • 作者:Antoine Rames ; Gaëlle Guillossou ; Sylvaine Ronga-Pezeret
  • 期刊名称:Environnement, Risques & Santé
  • 印刷版ISSN:1635-0421
  • 电子版ISSN:1952-3398
  • 出版年度:2012
  • 卷号:11
  • 期号:2
  • 页码:110-119
  • DOI:10.1684/ers.2012.0521
  • 出版社:John Libbey Eurotext
  • 摘要:Figures See all figures Authors Antoine Rames , Gaëlle Guillossou , Sylvaine Ronga-Pezeret , Corinne Hulot EDF-DIG 20, place de la Défense 92050 Paris La Défense France, EDF Service des études médicales 45, rue Kléber 92300 Levallois-Perret France, Ineris Direction des risques chroniques Parc technologique Alata 60550 Verneuil-en-Halatte France Key words: environmental exposure, environmental monitoring, indoor air pollution DOI : 10.1684/ers.2012.0521 Page(s) : 110-9 Published in: 2012 The indoor air quality of buildings on sites with soil or groundwater contaminated with volatile or semivolatile compounds can be degraded by potential vapor intrusion (VI) from these environmental media. For sites of former manufactured gas plants (MGP), the compounds that must be considered are BTEX (benzene, toluene, ethylbenzene, and xylenes), 8 of the 16 polycyclic aromatic hydrocarbons (PAHs) generally studied, and, to a lesser degree, phenol and hydrogen cyanide. Given the plausibility of VI and in accordance with current recommendations of the French Ministry of the Environment, measurements of indoor air quality (and outdoor air, for additional analyses) were conducted on two occasions during the winter and summer of 2010. These measurements simultaneously used multiple air sampling devices (Summa® canisters, Gore® modules, air pumps coupled to various matrices; such as XAD2, silica gel, etc.). Phenol and hydrogen cyanide have not previously been quantified (limit of quantification between 0.12 and 2.00 μg/m 3). BTEX and PAHs were found ubiquitously at concentrations on the order of 1 to 10 μg/m 3 for BTEX and naphthalene and one to ten ng/m 3 for PAHs other than naphthalene) at all 14 MGP and both control sites, regardless of where onsite the air was sampled (office, basement or crawl space, or outdoors). These levels (the maximum considered) do not allow us to conclude that the indoor air is degraded according to the official French guidelines for managing potentially contaminated sites and soils. Thus, no excess health risk is expected for residents of these sites because of exposure to possible VI, which cannot be ruled out in view of the ubiquity of some compounds.
  • 关键词:environmental exposure; environmental monitoring; indoor air pollution
国家哲学社会科学文献中心版权所有