  • 标题:Percutaneous Retrograde Intramedullary Pin Fixation for Isolated Metacarpal Shaft Fracture of the Little Finger
  • 本地全文:下载
  • 作者:Han, Soo Hong ; Yoon, Hyung Ku ; Shin, Dong Eun
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:2010
  • 卷号:23
  • 期号:4
  • 页码:367-372
  • DOI:10.12671/jkfs.2010.23.4.367
  • 语种:English
  • 出版社:The Korean Fracture Society
  • 摘要:Purpose

    To evaluate the anatomic and functional outcome of retrograde intramedullary single wire fixation for metacarpal shaft fractures of the little finger.

    Materials and Methods

    hirty one consecutive patients with closed metacarpal shaft fractures of the little finger who have been treated with retrograde intramedullary single wire fixation were evaluated. Fracture union and angulation were analyzed radiologically, and clinical evaluations were performed including range of motion, DASH score and complications.

    Results

    Fracture union was achieved in all cases and callus formation was obvious at postoperative 41 days. Average angulation of fracture site was 3° in the coronal plane and 1.2° in the sagittal plane at the last follow up and no measurable metacarpal shortening was observed. Mean TAM was 253° and DASH score was 2.6. There were two cases of pin migration as intermediate complications.

    Conclusion

    Closed reduction with subsequent percutaneous retrograde K-wire fixation produced good radiological and functional results. We recommend this minimally invasive technique which provides adequate fixation of displaced little finger metacarpal shaft fractures with good functional results and low morbidity.

  • 关键词:Metacarpal shaft fracture; little finger; K-wire; Retrograde fixation