首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Measurement and Analysis of Serous Fluid in Central Serous Chorioretinopathy using OCT
  • 本地全文:下载
  • 作者:Choi, Hyuck-Won ; Moon, Sang-Woong ; Kim, Jae-Suk
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2008
  • 卷号:49
  • 期号:2
  • 页码:282-287
  • DOI:10.3341/jkos.2008.49.2.282
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    To evaluate the correlation between the degree of serous fluid and best corrected visual acuity at the first visit in central serous chorioretinopathy using optical coherence tomography.

    Methods

    Retrospective analysis was performed for 30 eyes of 30 patients with central serous chorioretinopathy. Cross-sectional retinal images through the center of the fovea were obtained from all eyes by optical coherence tomography. The height, sectional area, and the tangent of theta (tan θ) were estimated. They were statistically analyzed and correlated with best corrected visual acuity.

    Results

    Mean (±SD) height of serous fluid was 341.40±120.60 µm, mean (±SD) sectional area was 0.55 ±0.29 mm2, and mean (±SD) tan θ was 0.22±0.04. The correlation coefficients between best corrected visual acuity at the first visit and sectional area were r=-0.740 (P=0.001).

    Conclusions

    Optical coherence tomography is useful for the quantitative evaluation of serous neurosensory retinal detachment and estimating visual acuity in central serous chorioretinopathy.

  • 关键词:Central serous chorioretinopathy; Serous fluid; Optical coherence tomography