  • 标题:Accuracy of the epidural catheter position during the lumbar approach in infants and children: a comparison among L2-3, L3-4, and L4-5 approaches
  • 本地全文:下载
  • 作者:Kim, Yeon A ; Kim, Ji Young ; Kil, Hae Keum
  • 期刊名称:Korean Journal of Anesthesiology
  • 印刷版ISSN:2005-6419
  • 出版年度:2010
  • 卷号:58
  • 期号:5
  • 页码:458-463
  • DOI:10.4097/kjae.2010.58.5.458
  • 语种:English
  • 出版社:The Korean Society of Anesthesiologists,
  • 摘要:Background

    The aim of this study was to compare the accuracy of the position of the epidural catheter inserted from three different lumbar intervertebral spaces, L2-3, L3-4, and L4-5, in infants and children.

    Methods

    Seventy-five children were randomly allocated to 3 groups according to the epidural catheter insertion site (L2-3, L3-4, and L4-5). The epidural catheter tip was identified using 50% diluted Iohexol and fluoroscopy. The incidence of correct position was compared among the groups and between infants and children.

    Results

    The incidence of correct position was significantly higher in the L2-3 group as compared to the L3-4 and L4-5 groups (P = 0.023 and P = 0.046 respectively). The incidence of correct position was higher in infants compared to children (P = 0.017).

    Conclusions

    The L2-3 intervertebral space is preferable during epidural catheter insertion in children older than 1 year, but a low lumbar level should be considered in infants because they have a higher risk of neural damage.