首页    期刊浏览 2024年12月03日 星期二
登录注册

文章基本信息

  • 标题:Psychometric evaluation of the Osteoporosis Patient Treatment Satisfaction Questionnaire (OPSAT-Q™), a novel measure to assess satisfaction with bisphosphonate treatment in postmenopausal women
  • 本地全文:下载
  • 作者:Emuella M Flood ; Kathleen M Beusterien ; Hannah Green
  • 期刊名称:Health and Quality of Life Outcomes
  • 印刷版ISSN:1477-7525
  • 电子版ISSN:1477-7525
  • 出版年度:2006
  • 卷号:4
  • 期号:1
  • 页码:42
  • DOI:10.1186/1477-7525-4-42
  • 语种:English
  • 出版社:BioMed Central
  • 摘要:The Osteoporosis Patient Satisfaction Questionnaire (OPSAT-Q) is a new measure of patient satisfaction with bisphosphonate treatment for osteoporosis. The objective of this study was to evaluate the psychometric characteristics of the OPSAT-Q. The OPSAT-Q contains 16 items in four subscales: Convenience, Confidence with Daily Activities, Side Effects, and Overall Satisfaction. All four subscale scores and an overall composite satisfaction score (CSS) can be computed. The OPSAT-Q, Osteoporosis Targeted Quality of Life (OPTQoL), and sociodemographic/clinical questionnaires, including 3 global items on convenience, functioning and side effects, were self-administered to women with osteoporosis or osteopenia recruited from four US clinics. Analyses included item and scale performance, internal consistency reliability, reproducibility, and construct validity. Reproducibility was measured using the intraclass correlation coefficient (ICC) via a follow-up questionnaire completed by participants 2 weeks post baseline. 104 women with a mean age of 65.1 years participated. The majority were Caucasian (64.4%), living with someone (74%), and not currently employed (58.7%). 73% had osteoporosis and 27% had osteopenia. 80% were taking weekly bisphosphonates and 18% were taking daily medication (2% missing data). On a scale of 0–100, individual patient subscale scores ranged from 17 to 100 and CSS scores ranged from 44 to 100. All scores showed acceptable internal consistency reliability (Cronbach's alpha > 0.70) (range 0.72 to 0.89). Reproducibility ranged from 0.62 (Daily Activities) to 0.79 (Side Effects) for the subscales; reproducibility for the CSS was 0.81. Significant correlations were found between the OPSAT-Q subscales and conceptually similar global measures (p < 0.001). The findings from this study confirm the validity and reliability of the OPSAT-Q and support the proposed composition of four subscales and a composite score. They also support the use of the OPSAT-Q to examine the impact of bisphosphonate dosing frequency on patient satisfaction.
  • 关键词:Osteoporosis ; Alendronate ; Risedronate ; Internal Consistency Reliability ; Treatment Satisfaction
国家哲学社会科学文献中心版权所有