  • 标题:Impact of different mechanical ventilation strategies for night purging on indoor air quality in public buildings
  • 本地全文:下载
  • 作者:Sami Lestinen ; Simo Kilpeläinen ; Risto Kosonen
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2021
  • 卷号:246
  • 页码:11003
  • DOI:10.1051/e3sconf/202124611003
  • 出版社:EDP Sciences
  • 摘要:Night-time ventilation has been used in non-residential buildings to enhance indoor air quality before occupied periods. However, many hypotheses exist on how this ventilation should be used. A typical choice has been to shut down the ventilation after occupancy and restart the ventilation again 2 hours before occupancy. Another option has been to ventilate the buildings continuously. In this study, the shut-down, continuous, and intermittent ventilation strategies were compared by evaluating indoor air quality. The daily occupied-hour ventilation was kept as usual. Each test case lasted for 2 weeks. Indoor air quality was assessed by measuring TVOC concentrations. Also, the thermal conditions, carbon dioxide, and pressure differences over the building envelope and over the air distribution devices were measured. The results show that the averaged TVOC concentrations were at the same level in the mornings with all those ventilation strategies. The evening concentrations reached a minimum level after a 2-hour purging period. TVOC concentrations were higher during the day than at night. This reveals that space usage had the largest effect on TVOC concentrations. The results indicate that a 2-hour purging is enough to cleanse indoor air before occupancy, and therefore the continuous night-time ventilation is not necessary.
  • 其他摘要:Night-time ventilation has been used in non-residential buildings to enhance indoor air quality before occupied periods. However, many hypotheses exist on how this ventilation should be used. A typical choice has been to shut down the ventilation after occupancy and restart the ventilation again 2 hours before occupancy. Another option has been to ventilate the buildings continuously. In this study, the shut-down, continuous, and intermittent ventilation strategies were compared by evaluating indoor air quality. The daily occupied-hour ventilation was kept as usual. Each test case lasted for 2 weeks. Indoor air quality was assessed by measuring TVOC concentrations. Also, the thermal conditions, carbon dioxide, and pressure differences over the building envelope and over the air distribution devices were measured. The results show that the averaged TVOC concentrations were at the same level in the mornings with all those ventilation strategies. The evening concentrations reached a minimum level after a 2-hour purging period. TVOC concentrations were higher during the day than at night. This reveals that space usage had the largest effect on TVOC concentrations. The results indicate that a 2-hour purging is enough to cleanse indoor air before occupancy, and therefore the continuous night-time ventilation is not necessary.
国家哲学社会科学文献中心版权所有