首页    期刊浏览 2024年11月30日 星期六
登录注册

文章基本信息

  • 标题:Implementation of a red blood cell-optical (RBO) channel for detection of latent iron deficiency anaemia by automated measurement of autofluorescence-emitting red blood cells
  • 本地全文:下载
  • 作者:Takahiro Tougan ; Sawako Itagaki ; Yuji Toya
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2020
  • 卷号:10
  • 期号:1
  • 页码:1-13
  • DOI:10.1038/s41598-020-72382-z
  • 出版社:Springer Nature
  • 摘要:Iron deficiency is the most common and widespread nutritional disorder worldwide. The automated haematology analyser XN-30 (Sysmex, Kobe, Japan) was developed to detect malaria-infected red blood cells (RBCs) in human blood samples using flow cytometry. The optical system of the analyser detects autofluorescence (AF)-emitting RBCs containing iron-deficient haem groups and would aid in the diagnosis of anaemia resulting from iron deficiency. Here, an RBC-optical (RBO) channel was devised and implemented on the analyser. In vitro analyses showed that the analyser detected AF-emitting RBCs treated with 5-aminolevulinic acid. Furthermore, the analyser detected AF-emitting RBCs in mice fed a low iron diet and infected with a rodent malaria parasite; it could also be effectively used in humans. This study demonstrates that the analyser can quantitatively and reproducibly detect AF-emitting RBCs and measure other haematological parameters, suggesting its usefulness for the initial evaluation of latent iron deficiency anaemia in conjunction with the diagnosis of malaria.
  • 其他摘要:Abstract Iron deficiency is the most common and widespread nutritional disorder worldwide. The automated haematology analyser XN-30 (Sysmex, Kobe, Japan) was developed to detect malaria-infected red blood cells (RBCs) in human blood samples using flow cytometry. The optical system of the analyser detects autofluorescence (AF)-emitting RBCs containing iron-deficient haem groups and would aid in the diagnosis of anaemia resulting from iron deficiency. Here, an RBC-optical (RBO) channel was devised and implemented on the analyser. In vitro analyses showed that the analyser detected AF-emitting RBCs treated with 5-aminolevulinic acid. Furthermore, the analyser detected AF-emitting RBCs in mice fed a low iron diet and infected with a rodent malaria parasite; it could also be effectively used in humans. This study demonstrates that the analyser can quantitatively and reproducibly detect AF-emitting RBCs and measure other haematological parameters, suggesting its usefulness for the initial evaluation of latent iron deficiency anaemia in conjunction with the diagnosis of malaria.
国家哲学社会科学文献中心版权所有