  • 标题:A System for Monitoring Breathing Activity Using an Ultrasonic Radar Detection with Low Power Consumption
  • 本地全文:下载
  • 作者:Ali Al-Naji ; Ali J. Al-Askery ; Sadik Kamel Gharghan
  • 期刊名称:Journal of Sensor and Actuator Networks
  • 电子版ISSN:2224-2708
  • 出版年度:2019
  • 卷号:8
  • 期号:2
  • 页码:32-48
  • DOI:10.3390/jsan8020032
  • 出版社:MDPI Publishing
  • 摘要:Continuous monitoring of breathing activity plays a major role in detecting and classifying a breathing abnormality. This work aims to facilitate detection of abnormal breathing syndromes, including tachypnea, bradypnea, central apnea, and irregular breathing by tracking of thorax movement resulting from respiratory rhythms based on ultrasonic radar detection. This paper proposes a non-contact, non-invasive, low cost, low power consumption, portable, and precise system for simultaneous monitoring of normal and abnormal breathing activity in real-time using an ultrasonic PING sensor and microcontroller PIC18F452. Moreover, the obtained abnormal breathing syndrome is reported to the concerned physician’s mobile telephone through a global system for mobile communication (GSM) modem to handle the case depending on the patient’s emergency condition. In addition, the power consumption of the proposed monitoring system is reduced via a duty cycle using an energy-efficient sleep/wake scheme. Experiments were conducted on 12 participants without any physical contact at different distances of 0.5, 1, 2, and 3 m and the breathing rates measured with the proposed system were then compared with those measured by a piezo respiratory belt transducer. The experimental results illustrate the feasibility of the proposed system to extract breathing rate and detect the related abnormal breathing syndromes with a high degree of agreement, strong correlation coefficient, and low error ratio. The results also showed that the total current consumption of the proposed monitoring system based on the sleep/wake scheme was 6.936 mA compared to 321.75 mA when the traditional operation was used instead. Consequently, this led to a 97.8% of power savings and extended the battery life time from 8 h to approximately 370 h. The proposed monitoring system could be used in both clinical and home settings.
  • 关键词:non-contact monitoring system; breathing abnormality; eupnea; tachypnea; bradypnea; central apnea; ultrasonic (PING) sensor; microcontroller PIC18F452; global system for mobile communication (GSM); power consumption model non-contact monitoring system ; breathing abnormality ; eupnea ; tachypnea ; bradypnea ; central apnea ; ultrasonic (PING) sensor ; microcontroller PIC18F452 ; global system for mobile communication (GSM) ; power consumption model
国家哲学社会科学文献中心版权所有