首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Influence of Acute Normobaric Hypoxia on Physiological Variables and Lactate Turn Point Determination in Trained Men
  • 本地全文:下载
  • 作者:Michael Ofner ; Michael Ofner ; Manfred Wonisch
  • 期刊名称:Journal of Sports Science and Medicine
  • 印刷版ISSN:1303-2968
  • 出版年度:2014
  • 卷号:13
  • 期号:4
  • 页码:774-781
  • 语种:English
  • 出版社:University of Uludag
  • 摘要:The goal of this study is to evaluate the response of physiological variables to acute normobaric hypoxia compared to normoxia and its influence on the lactate turn point determination according to the three-phase model of energy supply (Phase I: metabolically balanced at muscular level; Phase II: metabolically balanced at systemic level; Phase III: not metabolically balanced) during maximal incremental exercise. Ten physically active (VO2max 3.9 [0.49] l·min-1), healthy men (mean age [SD]: 25.3 [4.6] yrs.), participated in the study. All participants performed two maximal cycle ergometric exercise tests under normoxic as well as hypoxic conditions (FiO2 = 14%). Blood lactate concentration, heart rate, gas exchange data, and power output at maximum and the first and the second lactate turn point (LTP1, LTP2), the heart rate turn point (HRTP) and the first and the second ventilatory turn point (VETP1, VETP2) were determined. Since in normobaric hypoxia absolute power output (P) was reduced at all reference points (max: 314 / 274 W; LTP2: 218 / 184 W; LTP1: 110 / 96 W), as well as VO2max (max: 3.90 / 3.23 l·min-1; LTP2: 2.90 / 2.43 l·min-1; LTP1: 1.66 / 1.52 l·min-1), percentages of Pmax at LTP1, LTP2, HRTP and VETP1, VETP2 were almost identical for hypoxic as well as normoxic conditions. Heart rate was significantly reduced at Pmax in hypoxia (max: 190 / 185 bpm), but no significant differences were found at submaximal control points. Blood lactate concentration was not different at maximum, and all reference points in both conditions. Respiratory exchange ratio (RER) (max: 1.28 / 1.08; LTP2: 1.13 / 0.98) and ventilatory equivalents for O2 (max: 43.4 / 34.0; LTP2: 32.1 / 25.4) and CO2 (max: 34.1 / 31.6; LTP2: 29.1 / 26.1) were significantly higher at some reference points in hypoxia. Significant correlations were found between LTP1 and VETP1 (r = 0.778; p < 0.01), LTP2 and HRTP (r = 0.828; p < 0.01) and VETP2 (r = 0.948; p < 0.01) for power output for both conditions. We conclude that the lactate turn point determination according to the three-phase-model of energy supply is valid in normobaric, normoxic as well as hypoxic conditions. The turn points for La, HR, and VE were reproducible among both conditions, but shifted left to lower workloads. The lactate turn point determination may therefore be used for the prescription of exercise performance in both environments.
  • 关键词:Hypoxia;threshold determination;performance;heart rate;spiroergometry
国家哲学社会科学文献中心版权所有