期刊名称:IOP Conference Series: Earth and Environmental Science
印刷版ISSN:1755-1307
电子版ISSN:1755-1315
出版年度:2019
卷号:240
期号:6
页码:1-8
DOI:10.1088/1755-1315/240/6/062012
出版社:IOP Publishing
摘要:Francis turbines are increasingly demanded to work at part load in order to satisfy the electricity generation demand and to compensate the non-constant generation of other renewable sources such as wind or solar. At part load, Francis turbines present complex flow patterns dominated by cavitation and especially by the draft tube vortex rope. The vortex rope phenomenon affects the structural behavior of the machine as well as the hydraulic circuit response and, for certain conditions, it could become unstable. At this situation, the output power can significantly swing endangering the electrical grid stability. This condition has to be well-known and avoided as far as possible. In this paper, the phenomenon of the power swing at part load in prototypes is studied. For this purpose, different Francis turbine prototypes have been selected. The units have different specific speeds and therefore different power, head and geometry. All of them present the power swing phenomenon at part load. Different sensors, such as accelerometers, proximity probes, pressure sensors or strain gauges, have been placed in different positions of all the machines in order to detect and quantify the phenomenon. The relationship between the hydraulic phenomenon and the output power swing is presented for all the turbines studied. Results obtained permit to asses on the on-site detection of power swing as well as the possibility to avoid it in real-time.