摘要:Middle molecules (MMs) are associated with the pathology of uraemia, and are not effectively removed by standard extracorporeal treatments. Increased convection used in haemodiafiltration (HDF) can enhance the removal of MMs; however, high-volume HDF is not available to all patients. The new medium cut-off (MCO) membrane has been developed to allow increased removal of MMs using standard haemodialysis (HD). Improved removal of MMs has been shown with the MCO membrane compared with standard high-flux dialysers, but it is not known whether the increased pore size affects the retention of commonly used medications or that of coagulation factors in dialysis patients. Using an in vitro model, the retention of erythropoietin, heparin, insulin, vancomycin and several coagulation factors (Factors II, VII and X, protein C and antithrombin III) was investigated with the MCO membrane dialyser, compared with high-flux dialysers with polysulfone (in HDF) or polyethersulfone membranes (in HD and HDF). The retention of all molecules investigated was comparable between the MCO membrane and the high-flux dialysers. Results from the in vitro studies suggest that switching from a high-flux dialyser to the MCO membrane should not require changes to the medication dosing or anti-coagulation protocols of dialysis patients.