首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Measurement of mean subcutaneous fat thickness: eight standardised ultrasound sites compared to 216 randomly selected sites
  • 本地全文:下载
  • 作者:Paul Störchle ; Wolfram Müller ; Marietta Sengeis
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2018
  • 卷号:8
  • 期号:1
  • 页码:16268
  • DOI:10.1038/s41598-018-34213-0
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:and SAT means (from eight sites) ranging from 3 mm to 10 mm were selected. The means from eight sites overestimated the means obtained from 216 sites (i.e. 2160 US measurements in the ten participants); the calibration factor of 0.65 corrects this; standard deviation (SD) was 0.05, i.e. 8%. The SD of the calibration factor transforms linearly when estimating the error range of the whole body's SAT volume (body surface area times the calibrated mean SAT thickness). The SAT masses ranged from 3.2 to 12.4 kg in this group. The standard deviations resulting from solely the calibration factor uncertainty were ±0.3 and ±1.0 kg, respectively. For these examples, the SAT percentages were 4.9(±0.4)% and 13.3(±1.0)%.
国家哲学社会科学文献中心版权所有