首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Posterior Chamber Phakic Intraocular Lens Implantation in Eyes with an Anterior Chamber Depth of Less Than 3 mm: A Multicenter Study
  • 本地全文:下载
  • 作者:Kazutaka Kamiya ; Kimiya Shimizu ; Akihito Igarashi
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2018
  • 卷号:8
  • 期号:1
  • 页码:13322
  • DOI:10.1038/s41598-018-31782-y
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:This study was aimed to assess the clinical outcomes of Visian ICL (hole ICL; STAAR Surgical, Inc.) implantation for the correction of myopic refractive errors in eyes having an anterior chamber depth (ACD) below the current manufacturer’s recommendation (<3.0 mm). We comprised 365 eyes of 201 consecutive patients (mean age ± standard deviation, 35.7 ± 7.5 years) with spherical equivalents of −8.66 ± 3.54 D. We evaluated the safety, efficacy, predictability, stability, intraocular pressure (IOP), endothelial cell density (ECD), and complications. The safety and efficacy indices were 1.12 ± 0.22 and 0.98 ± 0.22. At 1 year, 90% and 98% of eyes were within ± 0.5 and 1.0 D of the attempted correction, respectively. Changes in the manifest refraction from 1 week to 1 year postoperatively were −0.08 ± 0.34 D. The mean ECD loss was 0.2 ± 8.7%. No eyes showed a significant ECD loss (≥30%). We found no significant correlation between the ACD and the change in ECD (Pearson correlation coefficient r = −0.048, p = 0.360). No significant IOP rise or vision-threatening complication occurred at any time. These findings indicate that the surgical indication of ICL implantation should be reconsidered in terms of ACD.
国家哲学社会科学文献中心版权所有