摘要:The paper presents results of analysis of possible cooperation of
a photovoltaic system with the space cooling devices. The size of the
photovoltaic system was determined on the basis of electricity demand of
the selected single family house. The demand for the electricity use for
cooling and air conditioning had not been taken into account while
calculating the size of PV system. On the basis of the heat balance of the
building, the demand for cooling in the following hours of a year was
determined. The demand for cooling and heating is affected by the heat
transfer through walls, windows, floor, roof, and air exchanged through
ventilation. Also solar and internal gains were taken into account. Based on
Next, a cooling unit was selected. A cooling device was selected to provide
enough energy to maintain the thermal comfort of the building in summer.
Taking into account parameters of the selected device, the demand for
electricity was determined. Based on time and hours of operation of
electrical appliances in the building, a chart of electricity demand was
created. The demand for cooling was included. Calculated values of the
energy demand required to power all devices in the building were
compared with the energy gains from the photovoltaic system. In order to
calculate the energy generated by the PV system (in following hours of
a year) the isotropic model of solar irradiation was used. The input solar
radiation data on horizontal surface were downloaded from the website of
the Ministry of Investment and Economic Development. In the last
paragraphs, savings obtained in result of using the energy generated by the
PV system to drive the space cooling system were determined and
conclusions from the calculations were presented.
其他摘要:The paper presents results of analysis of possible cooperation of a photovoltaic system with the space cooling devices. The size of the photovoltaic system was determined on the basis of electricity demand of the selected single family house. The demand for the electricity use for cooling and air conditioning had not been taken into account while calculating the size of PV system. On the basis of the heat balance of the building, the demand for cooling in the following hours of a year was determined. The demand for cooling and heating is affected by the heat transfer through walls, windows, floor, roof, and air exchanged through ventilation. Also solar and internal gains were taken into account. Based on Next, a cooling unit was selected. A cooling device was selected to provide enough energy to maintain the thermal comfort of the building in summer. Taking into account parameters of the selected device, the demand for electricity was determined. Based on time and hours of operation of electrical appliances in the building, a chart of electricity demand was created. The demand for cooling was included. Calculated values of the energy demand required to power all devices in the building were compared with the energy gains from the photovoltaic system. In order to calculate the energy generated by the PV system (in following hours of a year) the isotropic model of solar irradiation was used. The input solar radiation data on horizontal surface were downloaded from the website of the Ministry of Investment and Economic Development. In the last paragraphs, savings obtained in result of using the energy generated by the PV system to drive the space cooling system were determined and conclusions from the calculations were presented.