首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Standardization of CalyculinA induced PCC assay and its advantages over Okadaic acid PCC assay in Biodosimetry applications
  • 本地全文:下载
  • 作者:Rajesha K Nairy ; Narayana Yerol ; Nagesh N Bhat
  • 期刊名称:Journal of Occupational Health
  • 印刷版ISSN:1341-9145
  • 电子版ISSN:1348-9585
  • 出版年度:2016
  • 卷号:58
  • 期号:6
  • 页码:563-569
  • DOI:10.1539/joh.16-0049-OA
  • 语种:English
  • 出版社:Japan Society for Occupational Health
  • 摘要:

    Objective: In the present study an attempt was made to estimate coefficients of dose response curves for PCC aberrations induced by CalyculinA and Okadaic acid, using 60Co gamma radiation and 8 MeV pulsed electron beam for biodosimetry application. Materials and Methods: The modified method outlined by Puig et al. 2013 was used to conduct Calyculin A and Okadaic acid induced PCC assay in human blood lymphocytes.Chemical treatment was given for the last 1 h of a 48 h culture. The study was carried out in the dose range 2.5 to 20 Gy using 60Co gamma rays and 8 MeV pulsed electron beam. Results and Conclusions: Results show a linear dose dependent increase with a slope of 0.047 ± 0.001 from Calycalin A PCC and 0.048 ± 0.002 form Okadaic acid PCC. The slope of the fragments curve was 0.327 ± 0.006 from Calyculin A and 0.328 ± 0.006 from Okadaic acid PCC. Further, dose calibration studies were carried out for 8 MeV electron using Calyculin A PCC assay and the obtained slope from ring yield was 0.054 ± 0.002 and 0.427 ± 0.009 from fragment yield.

  • 关键词:CalyculinA;Gamma radiation;Microtron accelerator;Okadaic acid;Premature chromosome condensation;Rings