首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Comparison of Ocular Aberration and Clinical Outcome between Different Aspheric Intraocular Lenses in Both Eyes
  • 本地全文:下载
  • 作者:Kang, Min Ku ; Yoo, Young Sik ; Chung, So Hyang
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2017
  • 卷号:58
  • 期号:5
  • 页码:530-538
  • DOI:10.3341/jkos.2017.58.5.530
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    We compared the ocular aberration and clinical outcome between different aspheric intraocular lenses (IOL) in both eyes.

    Methods

    This prospective randomized controlled study was comprised of patients with bilateral cataract who received two different aspheric IOLs implanted in both eyes: negatively aspheric Tecnis® ZCB00 and spherically neutral Akreos® MI60. Total and corneal aberrations computed by Wavescan® and Pentacam® were assessed at 6 months to investigate the effects of the IOL's spherical aberration on the eye and to analyze the incidence and degree of posterior capsule opacification. By using spherical aberration of the cornea and the IOLs, values calculated via Ray-tracing software and Wavescan® were compared. Total spherical aberration was analyzed by the MATLAB program and converting the pupil size to 6.0, 4.5, 3.0 mm.

    Results

    A total of 25 patients were included. Regarding pre-operative corneal aberration, ZCB00 group was 0.232 ± 0.119 µm while MI60 group was 0.240 ± 0.117 µm, and there was no difference between the two IOLs. At 6 months after total ocular spherical aberration, MI60 group (pupil size 6.0 mm; 0.296 ± 0.097 µm, 4.5 mm; 0.094 ± 0.032 µm, 3.0 mm; 0.019 ± 0.006 µm) had more positive values than ZCB00 group (pupil size 6.0 mm; 0.051 ± 0.105 µm, 4.5 mm; 0.009 ± 0.034 µm, 3.0 mm; 0.002 ± 0.007 µm) ( p < 0.001). When calculated using the ray tracing method, based on the results after surgery, MI60 group's total spherical aberrations were higher than ZCB00 group. However, from 1 month to 6 months after surgery, the uncorrected distance visual acuity, spherical equivalent and posterior capsule opacification showed no differences between the two IOLs.

    Conclusions

    In eyes with aspheric IOLs with negative spherical aberration, spherical aberration was lower than spherically neutral aspheric IOLs. Regarding postoperative visual acuity, spherical equivalent and posterior capsule opacification, there were no significant differences between the two groups.

  • 关键词:Aspheric intraocular lens; Cataract surgery; Ocular aberrations; Posterior capsular opacity
国家哲学社会科学文献中心版权所有