首页    期刊浏览 2024年11月30日 星期六
登录注册

文章基本信息

  • 标题:Improved accuracy in periodontal pocket depth measurement using optical coherence tomography
  • 本地全文:下载
  • 作者:Kim, Sul-Hee ; Kang, Se-Ryong ; Park, Hee-Jung
  • 期刊名称:The Journal of the Korean Academy of Periodontology
  • 印刷版ISSN:0250-3352
  • 出版年度:2017
  • 卷号:47
  • 期号:1
  • 页码:13-19
  • DOI:10.5051/jpis.2017.47.1.13
  • 语种:English
  • 出版社:Korean Academy of Periodontology
  • 摘要:Purpose

    The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth.

    Methods

    We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing.

    Results

    The average periodontal pocket depth measured by OCT was 3.10±0.15 mm, 4.11±0.17 mm, 5.09±0.17 mm, and 6.05±0.21 mm for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing.

    Conclusions

    OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

    Go to: Graphical Abstract
  • 关键词:Computer-assisted image interpretation; Gingiva; Optical coherence tomography; periodontal pocket