首页    期刊浏览 2024年11月29日 星期五
登录注册

文章基本信息

  • 标题:Development of an Inhalation System of High Melting Point Metal Fumes and Its Use for Exposure of Rats to Chromium and Nickel Fumes
  • 本地全文:下载
  • 作者:Fumio SERITA ; Katsunori HOMMA ; Kazuo FUKUDA
  • 期刊名称:Industrial Health
  • 印刷版ISSN:0019-8366
  • 电子版ISSN:1880-8026
  • 出版年度:1990
  • 卷号:28
  • 期号:4
  • 页码:185-197
  • DOI:10.2486/indhealth.28.185
  • 出版社:National Institute of Occupational Safety and Health
  • 摘要:An experimental inhalation system was developed for fumes generated from powders of high melting point metals such as chromium, nickel, manganese and iron. The system consisted of a plasma flame metal sprayer as a fume generator, a granular bed type fume collector, a fluidized bed aerosol generator, an exposure and a control chamber of a horizontal-flow type and inhalant monitoring and controlling units. Performance of the chambers was ensured by a distribution test using flyash as a test aerosol. Using this system, rats were exposed to chromium fumes for one week or to nickel fumes for two months. The exposure concentrations of the chromium and nickel fumes were 1.85 ± 0.55 mg/m3 and 0.51±10.15 mg/m3 (mean±SD), near the target levels of 2 mg/m3 and 0.5 mg/m3, respectively. The mass median aerodynamic diameter and the geometric standard deviation of the chromium fumes were 2.1μm and 2.00, respectively. Those of the nickel fumes were 3.7μm and 1.74, respectively. Species analysis of these fume particles revealed that 26.4% of the total chromium was hexavalent and the residue was trivalent and that 1-3% of the total nickel was nickel(III) and the residue was nickel(II). Inhaled-metal concentrations in the lungs showed steady increases with the exposure periods and were within the normal range of variation. On the basis of these results, it is concluded that this system is useful for long-term inhalation experiments using high melting point metal fumes.
  • 关键词:High melting point metals;Fumes;Generation;Chromium;Nickel;Inhala-tion;Rat
国家哲学社会科学文献中心版权所有