首页    期刊浏览 2024年11月30日 星期六
登录注册

文章基本信息

  • 标题:REPRODUTIBILIDADE E CONCORDÂNCIA DO TESTE DE SALTO VERTICAL COM CONTRAMOVIMENTO EM FUTEBOLISTAS DE ELITE DA CATEGORIA SUB-21 - DOI: 10.4025/reveducfis.v19i3.5996
  • 其他标题:Reliability and agreement of vertical countermovement jump test in under-21 elite soccer players
  • 本地全文:下载
  • 作者:Alexandre Moreira ; Gustavo Maia ; Cristian Ramirez Lizana
  • 期刊名称:Revista da Educação Física/UEM
  • 印刷版ISSN:0103-3948
  • 电子版ISSN:1983-3083
  • 出版年度:2008
  • 卷号:19
  • 期号:3
  • 页码:413-421
  • 语种:Portuguese
  • 出版社:Maringá State University
  • 摘要:O estudo investigou a consistência interna e a concordância do salto vertical (SV) efetuado no tapete de contato (TP) e com a cinta de Abalakov (AB) em 27 futebolistas do sexo masculino (18 ± 0,7 anos). Utilizou-se o teste t a para observar as diferenças entre as duas medidas retidas para TP e AB e o teste t (amostras independentes) para as diferenças entre TP e AB. O nível de significância estabelecido foi de 5%. A reprodutibilidade relativa foi testada através do coeficiente intraclasse (CIC), e a reprodutibilidade absoluta, pelo coeficiente de variação (CV). A análise da concordância (AC) entre TP e AB foi feita através da plotagem de Bland-Altman. Não foi demonstrada diferença estatisticamente significante tanto no TP quanto no AB. O elevado CIC e baixo CV para ambos os equipamentos indicam alta consistência interna do SV. Os valores da AC sugerem que os equipamentos não apresentam concordância elevada.
  • 其他摘要:The purpose of the study was to evaluate the internal consistency and agreement of vertical jump test performed on contact mat (CM) and with Abalakov belt (AB) in 27 male soccer players (18,7+ 0,7 years). The paired student-t test was used to verify differences between the two retained measures for CM and AB. The independent t test was used to verify differences between CM and AB. The significance level adopted was 5%. It also was used the coefficient of variation (CV) to test the absolute reliability, the intraclass coefficient (ICC) to test the relative reliability, and the limits of agreement between CM and AB were analyzed using Bland-Altman plots. No significant differences between the trials were found to CM as well as to AB. High ICC values and low CV values to CM and AB showed high internal consistency. The limits of agreement suggest not enough agreement between the apparatus.
  • 关键词:Salto vertical; Futebol; Medidas repetidas;4.09.00.00-2 Educação Física
  • 其他关键词:Vertical jump; Soccer; Repeated measures.
国家哲学社会科学文献中心版权所有