首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Use of Video-oculography in the Diagnosis of Superior Oblique Myokymia
  • 本地全文:下载
  • 作者:Chung, Sae Rom ; Lee, Tae Eun ; You, In Cheon
  • 期刊名称:Journal of the Korean Ophthalmological Society
  • 印刷版ISSN:0378-6471
  • 出版年度:2016
  • 卷号:57
  • 期号:8
  • 页码:1316-1319
  • DOI:10.3341/jkos.2016.57.8.1316
  • 语种:Korean
  • 出版社:The Korean Ophthalmological Society
  • 摘要:Purpose

    Superior oblique myokymia is intermittent spontaneous contractions of the superior oblique muscle presenting as rapid and small-amplitude intorsions and depressions of the eye. The authors report a case of superior oblique myokymia that was objectively and quantitatively diagnosed with slit lamp examination and video-oculography and completely resolved with medical treatment.

    Case summary

    A 44-year-old woman presented with a seven-year history of intermittent oscillopsia which continued for few seconds. She had no history of head trauma or systemic ocular disease, and the anterior segment and fundus examination were unremarkable. Right eye intorsion lasting for a few seconds as detected by slit lamp examination. Eye movements were recorded using video-oculography, which showed a torsional nystagmus of 5 to 10 degrees with 2 to 5 vertical components in the right eye. Based on these findings, the patient was diagnosed with superior oblique myokymia. The patient was prescribed topical timolol ophthalmic solution, one drop twice per day, but the symptoms persisted. Timolol ophthalmic solution was stopped and replaced with carbamazepine, 200 mg twice a day, which resolved her symptoms.

    Conclusions

    Slit lamp examination and video-oculography can be used as objective and quantitative diagnostic tools in order to confirmed a diagnosis and lead to proper treatment.

  • 关键词:Carbamazepine; Slit lamp examination; Superior oblique myokymia; Video-oculography