首页    期刊浏览 2024年12月03日 星期二
登录注册

文章基本信息

  • 标题:Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
  • 本地全文:下载
  • 作者:Samantha Keogh ; Julie Flynn ; Nicole Marsh
  • 期刊名称:Trials
  • 印刷版ISSN:1745-6215
  • 电子版ISSN:1745-6215
  • 出版年度:2016
  • 卷号:17
  • 期号:1
  • 页码:1
  • DOI:10.1186/s13063-016-1470-6
  • 语种:English
  • 出版社:BioMed Central
  • 摘要:Background Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. Methods This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours ( n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. Results PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction ( p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. Conclusion Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. Trial registration Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538 . Registered on 19 January 2015.
  • 关键词:Flushing ; 0.9 % sodium chloride ; Peripheral ; Randomised controlled trial ; Catheter obstruction ; Vascular access devices ; Phlebitis
国家哲学社会科学文献中心版权所有