首页    期刊浏览 2024年12月12日 星期四
登录注册

文章基本信息

  • 标题:Failure Region Estimation of Linear Voltage Regulator using Model-based Virtual Sensing and Non-invasive Stability Measurement
  • 本地全文:下载
  • 作者:Syukri Zamri ; Mohd Hairi Mohd Zaman ; Muhammad Fauzi Mohd Raihan
  • 期刊名称:International Journal of Advanced Computer Science and Applications(IJACSA)
  • 印刷版ISSN:2158-107X
  • 电子版ISSN:2156-5570
  • 出版年度:2022
  • 卷号:13
  • 期号:2
  • DOI:10.14569/IJACSA.2022.0130232
  • 语种:English
  • 出版社:Science and Information Society (SAI)
  • 摘要:Voltage regulator (VR) stability plays an essential role in ensuring maximum power delivery and long-lasting electronic lifespan. Capacitor with a specific equivalent series resistance (ESR) range is typically connected at the VR output terminal to compensate for instability of the VR due to sudden changes in load current. The stability of VR can be measured by analyzing output voltage during load transient tests. However, the optimum ESR range obtained from the ESR tunnel graph in its datasheet can only be characterized by testing a set of data points consisting of ESR and load currents. Characterization process is performed manually by changing the value of ESR and load current for each operating point. However, the inefficient process of estimating the critical value of ESR must be improved given that it requires a large amount of time and expertise. Furthermore, the stability analysis is currently conducted on the basis of the number of oscillation counts of VR output voltage signal. Therefore, a model-based virtual sensing approach that mainly focuses on black-box modeling through system identification method and training neural network on the basis of estimated transfer function coefficients is introduced in this study. The proposed approach is used to estimate the internal model of the VR and reduce the number of data points that need to be acquired. In addition, the VR stability is analyzed using noninvasive stability measurement method, which can measure phase margin from the frequency response of the VR circuit in closed-loop conditions. Results showed that the proposed method reduces the time it takes to produce an ESR tunnel graph by 84% with reasonable accuracy (MSE of 5×10−6, RMSE of 2.24×10−3, MAE of 1×10−3, and R2 of 0.99). Therefore, efficiency and effectiveness of ESR characterization and stability analysis of the VR circuit is improved.
  • 关键词:Voltage regulator; output capacitor; equivalent series resistance; failure region; system identification; neural network; noninvasive stability measurement
国家哲学社会科学文献中心版权所有