首页    期刊浏览 2024年12月02日 星期一
登录注册

文章基本信息

  • 标题:Cerclage Wiring in Internal Fixation of Displaced Acetabular Fractures
  • 本地全文:下载
  • 作者:Kim, Chong-Kwan ; Jin, Jin-Woo ; Yoon, Jong-Ho
  • 期刊名称:Journal of the Korean Fracture Society
  • 印刷版ISSN:1225-1682
  • 出版年度:2008
  • 卷号:21
  • 期号:2
  • 页码:95-102
  • DOI:10.12671/jkfs.2008.21.2.95
  • 语种:Korean
  • 出版社:The Korean Fracture Society
  • 摘要:Purpose

    To evaluate the usefulness of wire fixation in displaced acetabular fractures.

    Materials and Methods

    From January 2000 to December 2005, 19 cases of displaced acetabular fracture were treated with wire fixation. According to Letournel's classification there were 9 both column fracture, 5 transverse fracture, 3 anterior column with posterior hemitransverse and 2 T-type fracture. Only wire fixation in 13 cases and wire with plate or wire with screw fixation in 6 cases.

    Results

    We evaluate the accuracy of reduction by Matta' criteria, anatomical reduction in 12 cases, incomplete reduction in 4 cases, poor reduction in 2 cases and surgical secondary congruence in 1 case. The clinical results showed excellent in 12 cases, good in 4 cases, fair in 2 cases and poor in 1 case. The radiological results showed excellent in 10 cases, good in 4 cases, fair in 3 cases and poor in 2 cases. There were 4 cases of complication; wound infection in 1case, post-traumatic arthritis in 1 case and heterotopic ossification in 2 cases.

    Conclusion

    The cerclage wiring is a preferable method in internal fixation of displaced acetabular fractures that can facilitate reduction and achieve stable fixation.

  • 关键词:Displaced acetabular fracture; cerclage wiring
国家哲学社会科学文献中心版权所有