首页    期刊浏览 2025年03月04日 星期二
登录注册

文章基本信息

  • 标题:Correction of bias in self-reported sitting time among office workers – a study based on compositional data analysis
  • 本地全文:下载
  • 作者:Coenen P ; Mathiassen SE ; van der Beek AJ
  • 期刊名称:Scandinavian journal of Work, Environment and Health
  • 印刷版ISSN:0355-3140
  • 出版年度:2020
  • 卷号:46
  • 期号:1
  • 页码:32-42
  • DOI:10.5271/sjweh.3827
  • 语种:English
  • 出版社:National Board of Occupational Safety and Health
  • 摘要:Objective Emerging evidence suggests that excessive sitting has negative health effects. However, this evidence largely relies on research using self-reported sitting time, which is known to be biased. To correct this bias, we aimed at developing a calibration model estimating "true" sitting from self-reported sitting.Methods Occupational sitting time was estimated by self-reports (the International Physical Activity Questionnaire) and objective measurements (thigh-worn accelerometer) among 99 Swedish office workers at a governmental agency, at baseline and 3 and 12 months afterwards. Following compositional data analysis procedures, both sitting estimates were transformed into isometric log-ratios (ILR). This effectively addresses that times spent in various activities are inherently dependent and can be presented as values of only 0−100%. Linear regression was used to develop a simple calibration model estimating objectively measured "true" sitting ILR (dependent variable) from self-reported sitting ILR (independent variable). Additional self-reported variables were then added to construct a full calibration model. Performance of the models was assessed by root-mean-square (RMS) differences between estimated and objectively measured values. Models developed on baseline data were validated using the follow-up datasets.Results Uncalibrated self-reported sitting ILR showed an RMS error of 0.767. Simple and full calibration models (incorporating body mass index, office type, and gender) reduced this error to 0.422 (55%) and 0.398 (52%), respectively. In the validations, model performance decreased to 57%/62% (simple models) and 57%/62% (full models) for the two follow-up data sets, respectively.Conclusions Calibration adjusting for errors in self-reported sitting led to substantially more correct estimates of "true" sitting than uncalibrated self-reports. Validation indicated that model performance would change somewhat in new datasets and that full models perform no better than simple models, but calibration remained effective.
  • 关键词:calibration; calibration model; compositional data analysis; occupational health; sedentary behavior
国家哲学社会科学文献中心版权所有