首页    期刊浏览 2024年11月30日 星期六
登录注册

文章基本信息

  • 标题:Experimental Study on Insulation Performance and Condensation Characteristics of a Vacuum Insulated Glass Window
  • 本地全文:下载
  • 作者:Chang-Ho Jeong ; Myoung-Souk Yeo ; Kwang-Woo Kim
  • 期刊名称:Journal of Asian Architecture and Building Engineering
  • 印刷版ISSN:1346-7581
  • 电子版ISSN:1347-2852
  • 出版年度:2015
  • 卷号:14
  • 期号:3
  • 页码:717-724
  • DOI:10.3130/jaabe.14.717
  • 语种:English
  • 出版社:日本建築学会、大韓建築学会、中国建築学会
  • 摘要:Through a mock-up test the surface temperature distribution and condensation characteristics were analyzed for a vacuum insulated glass (VIG) window, manufactured through an in-vacuum method, and compared with a double-glazed (DG) window. The outside air temperature was -21.2°C for a VIG window, at which the inside surface condensation begins to occur, given an inside air temperature of 20°C and an inside relative humidity of 50%; thus, given the typical weather conditions for Seoul, a VIG window is not likely to have condensation. The surface temperatures of the VIG window were found to be approximately 4 K–6 K higher than those of the DG window. In the case of the VIG window, the surface temperature of the center of glass is higher than that of the frame, because the vacuum insulated glass (VIG) has a superior insulation performance compared with the frame. However, the surface temperature of the edge of the vacuum insulated glass is lower than that of the frame, by approximately 0.9 K–1.5 K. Thus, to reduce heat loss and improve condensation resistance, measures to reduce heat loss at the glass connection should be established and frames should be utilized that have insulation performance equal to or better than VIG.
  • 关键词:window system;surface temperature;surface condensation;temperature ratio value;vacuum insulated glass window
国家哲学社会科学文献中心版权所有