摘要:This article presents a non-invasive tests report of precast cantilever balcony support in OWT-67 large-panel system. During field testing, the balcony's reinforced concrete structure was subjected to radiometric analysis in the context of thermal energy distribution as well as from the point of view of mycology - to the possible presence of spores of domestic fungi. The temperature distribution tests carried out by means of the electromagnetic wave detection in the infrared spectrum clearly confirmed the significant losses of thermal energy caused by the effect of the thermal constructional bridge located in the balcony. Mycological diagnosis was carried out using the rapid test of the Mycometer bacterial meter, which allows fluorimetric evaluation of the presence of the enzyme presence in filamentous fungi. In the conducted study, no spores of the house mushroom were found on the inside surface of the Z-type balcony supporting beam as a place where condensation of water vapor may occur. The summary also presents a design solution that allows to eliminate this physical problem.