摘要:One of the methods of solving the problem of improvement of heat-mass efficiency of thermal deaerators of TPSs is application of jet-film contact devices for interaction of vapor and liquid flows. The design of these devices has been studied. Estimate calculations of hydraulic resistance have been carried out. We have obtained the equation for calculation of resistance coefficient, depending on the height of element of contact device.