首页    期刊浏览 2024年12月12日 星期四
登录注册

文章基本信息

  • 标题:EFEITO DE DIFERENTES NÍVEIS DE PRESSÃO POSITIVA CONTINUA SOBRE A DEPURAÇÃO PULMONAR DO 99MTC-DTPA
  • 本地全文:下载
  • 作者:Dulciane Nunes Paiva ; Diogo Fanfa Bordin ; Ricardo Gass
  • 期刊名称:Revista de Epidemiologia e Controle de Infecção
  • 印刷版ISSN:2238-3360
  • 出版年度:2014
  • 卷号:4
  • 期号:2
  • DOI:10.17058/reci.v4i2.4646
  • 语种:Portuguese
  • 出版社:Revista de Epidemiologia e Controle de Infecção
  • 摘要:Backgound and Objectives: Positive airway pressure continues (CPAP) produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA), along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA) through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½) that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005). However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.
  • 其他摘要:Backgound and Objectives: Positive airway pressure continues (CPAP) produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA), along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA) through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½) that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005). However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.
国家哲学社会科学文献中心版权所有