首页    期刊浏览 2024年12月03日 星期二
登录注册

文章基本信息

  • 标题:ZargisCardioscan™ Aided Heart Murmurs Recognition has high negative predictive values when correlated and validated with Echocardiography: A Potential Dawn for Valvular Heart Disease Prevalence Studies in Rural India
  • 本地全文:下载
  • 作者:P Aggarwal ; R Kumar ; SD Kandpal
  • 期刊名称:Nepal Journal of Epidemiology
  • 电子版ISSN:2091-0800
  • 出版年度:2014
  • 卷号:4
  • 期号:3
  • 页码:363-369
  • DOI:10.3126/nje.v4i3.10665
  • 语种:English
  • 出版社:International Nepal Epidemiological Association (INEA)
  • 摘要:Background The purpose of this open-label study was to correlate the auscultation findings of ZargisCardioscan™ with the echocardiographic findings in our patient population who were referred for echocardiography so as to investigate and ensure the validity of this technology before instituting its applicability in community health events among rural Indian population. Materials and Methods This was a double blinded prospective correlation study in outpatients presenting for echocardiography. Methods: One hundred patients, who had presented for echocardiography at Cardiology Center of an academic university hospital in rural India, were enrolled in this double blinded prospective correlation study. Principal investigator who is a community medicine physician performed the auscultation of patients’ hearts in sitting position. Subsequently, the ZargisCardioscan™ software was used to analyze the heart sounds auscultated by the 3M™ Littmann® Model 3200 stethoscope. Thereafter, the scheduled echocardiography for which the patient had presented to hospital was performed by co-investigator cardiologist who was blinded to the results obtained by the ZargisCardioscan™.Finally, all these data were statistically analyzed by blinded investigator for the presence of correlation between the two modalities. Results The most important finding was the high 90s negative predictive values when the stethoscope-software combination was used for auscultation and analysis of heart murmurs. Additionally, presence of isolated systolic murmurs had higher incidence of appreciable significant valvular lesions and presence of isolated diastolic murmurs primarily had underlying minimal-mild regurgitant valvular lesion, if any. The Bland-Altman Plot confirmed good correlation between stethoscope-echocardiography findings. Conclusion Stethoscope-software combination, 3M™ Littmann® Model 3200 and ZargisCardioscan™, accurately predicts the absence of valvular heart disease on echocardiography. DOI: http://dx.doi.org/10.3126/nje.v4i3.10665 Nepal Journal of Epidemiology 2014; 4(3): 363-369
  • 关键词:ZargisCardioscan™;3M™ Littmann® Model 3200
国家哲学社会科学文献中心版权所有